Compressor operation, Overload protection reset, Warning – Briggs & Stratton 074000 User Manual

Page 10

Advertising
background image

Compressor Operation

You do not have to use the maximum operating pressure at
all times because the air tool being used often requires less
pressure. Here are general guidelines for setting pressure.

1.

With air compressor connected to proper power and
turned ON, attach desired air tool or accessory to quick
connect fitting. Use recommended air hose and quick
connect fitting.

2.

Activate air tool and turn Pressure Control knob
clockwise to increase outlet pressure.

3.

Observe OUTLET PRESSURE GAUGE and adjust
pressure to recommended setting of accessory tool.

NOTE:You must adjust outlet air pressure while tool is
operating or activated.

4.

Use lock ring on Pressure Control to lock in selected
pressure setting by tightening it against Pressure Control
knob.

5.

Always operate this unit on a level surface to avoid
lubrication problems.

Overload Protection Reset

This compressor is equipped with an overload protection
feature that protects the motor if it overheats. If the
compressor motor overheats and trips this circuit breaker,
wait 15 minutes for the motor to cool.Then push the
RESET button located on the motor shroud (see Figure 6).

Also see the TROUBLESHOOTING on page 16 for more
information

Observe these safety precautions when operating air
compressor:

OPERATION

10

• DO NOT use grounding adapters. Inspect cord before each use.

• DO NOT operate with protective covers / guards removed or

damaged.

• DO NOT operate in wet conditions. Store indoors.

• Disconnect from power source and drain pressure from tank

when not in use or before servicing.

Contact with compressor or its cord can cause
electric shock or burn.
Compressor must be grounded.

WARNING

• DO NOT adjust pressure greater than maximum rating of

attachments or inflatables.

Exceeding pressure rating of attachments or
inflatables can cause severe injury and/or property
damage.

WARNING

• DO NOT touch compressor or tubing.

• Allow compressor to cool before servicing.

Operating air compressor and tubing are HOT
and can cause burns.

WARNING

• STAY CLEAR

• Disconnect from power source and drain pressure from tank

when not in use or before servicing.

Compressor can start any time when plugged in.

WARNING

• DO NOT use compressed air for breathing.

• Always use NIOSH respirator approved for your application

when spraying.

• Read all instructions with respirator so you are certain it will

provide necessary protection against inhaling harmful vapors.

Compressed air is not breathable and can cause
bodily injury.
Some paints or solvents may be harmful if inhaled
or ingested, causing severe nausea, fainting or
poisoning.

WARNING

• DO NOT direct air stream at self or others.

• Always wear ANSI Z87.1 approved safety glasses with side

shields.

Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin and
can propel objects leading to severe injury
and / or property damage.

WARNING

Figure 6 - Overload Protection RESET Button

RESET Button

Advertising