Flex OlyLok Locking Impact Nail User Manual

Specifications, Composition, Technical data

Advertising
background image

COMPOSITION

Factory preassembled components consisting of:
Tube:

Precision formed from Galvanized (G-90) coated steel to prevent corrosion.

The tube is shaped to easily penetrate decking and existing membranes.

Disk:

Precision formed from Galvalume (AZ-55) coated steel to prevent corrosion.

Securely clamped to the tube, 2.7" diameter, rib reinforced to resist cupping.

Locking Staple:

Precision formed from high tensile steel wire.

Coated to prevent corrosion.

TECHNICAL DATA

Fastening Pattern:

Consult Flex for requirements for recommended patterns

in normal, exposed, and hurricane areas.

Field Testing:

On-site withdrawal testing should always be performed to

evaluate the ability of the roofing substrate to satisfactorily accept and retain

fasteners. Such testing may alter fastener selection and modify applicable

fastening patterns.

The OlyLok should always be embedded into the structural roof deck to a

depth of at least 1".

INSTALLATION

Installation Tools:

There are two tools that must be used to install the OlyLok

Locking Impact Nail. The OlyLok Driver is for installing base sheet and recovery

board to the substrate. For securing ISO or EPS to the substrate use the OlyLok

Insulation Tool, which has a larger impact area. Consult Flex for the specific

driver for your application.

Method:

Drive fastener perpendicular to roof deck seating cap flush with roofing

surface. Once tube is set, drive the locking staple thru the tube/disk unit into the

deck until the top of the staple is flush with the cap (see illustration).

Operation:

When locking staple is driven, its dual wire legs diverge anchoring

the fastener in place (see illustration). Uplift resistance may vary depending on

the density and integrity of the substrate.

Packaging:

1.4", 1.8", 2.8", and 3.8" OlyLoks packaged 500 per carton.

4.8" OlyLoks packaged 250 per carton.

SPECIFICATIONS

For Attaching Base Ply, Recovery Board and
Insulation to Wood Fiber/Poured Gypsum Decks

1.8"

2.7"

2.8"

5 LENGTHS

Roofing disk is
securely clamped
to the tube.

Recovery
Board

Existing
membrane

As locking staple is driven, its dual wire legs
diverge anchoring the fastener in place.

FIRST IMPACT SETS TUBE.

SECOND IMPACT ACTUATES STAPLE.

Factory
preinserted
staple.

MADE IN THE U.S.A.

1.4"

3.8"

4.8"

800-969-0108 • 610-916-9501 (Fax)

2670 Leiscz’s Bridge Road, Suite 400, Leesport, PA 19533

e-mail: [email protected] • www.flexroofingsystems.com

Advertising