For Attaching Base Ply, Recovery Board and
Insulation to Wood Fiber/Poured Gypsum Decks

Fastener density and spacing vary depending on applicable uplift require-

ments. Local codes, governing approval bodies, membrane manufactur-

ers, and individual roofdeck manufacturers all may have specific require-

ments that need to be addressed prior to beginning any roofing project.

The OlyLok should always be embedded into the structural roof

deck to a depth of at least 1". The following illustrates typical Factory

Mutual recommended fastening patterns widely accepted by membrane

and roofdeck manufacturers.

USING THE OLYLOK

Fastening Guide 2

Recovery board and insulation attachment under fully adhered

single ply membranes.

Class I-90 Windstorm Classification.

An FMRC Approved Recovery Board/Insulation suitable for use

with fully adhered single ply membranes is attached with 12 OlyLok

fasteners per 4'x 4' board in 4 rows of 3 fasteners per row.

(1 fastener per 1.33 ft.

2

)

Consult Flex for a complete listing of approved recovery

boards/insulations.

Fastening Guide 1

Recovery board and Insulation attachment under built-up and

modified bitumen roof covers.

Class I-90 Windstorm Classification.

An FMRC Approved Recovery Board/Insulation suitable for use

with minimum 3 ply built-up or modified membranes is attached with

8 OlyLok fasteners per 4'x 4' board in a diamond in a box pattern.

(1 fastener per 2 ft.

2

)

Consult Flex for a complete listing of approved recovery

boards/insulations.

6"

6"

+

+

+

+

+

+

+

+

+

+

+

+

12"

12"

12"

12 Fasteners

¨

¨

¨

¨

¨

¨¨

¨

¨

¨

¨

¨

¨

¨

6"

6"

¨

¨

¨

¨

¨

¨

¨

¨

+

+

+

+

+

+

+

+

6"

6"

12"

24"

8 Fasteners