Low Water Cut-Off Function

To turn off Low Water Cut-Off

1. Turn the LO TEMP dial to access the Program Mode – indicated in the display as
2. Turn the HI TEMP dial to select feature
3. Push the Test/Settings Button to turn Low Water Cut-Off

or

4. Reset LO TEMP and HI TEMP settings to desired temperatures (see page 7)

Restore Factory Default Settings

To restore all features to the factory default settings (see following chart for default settings)

1. Turn the LO TEMP dial to access the Program Mode – indicated in the display as
2. Turn the HI TEMP dial to select feature
3. Push the Test/Settings Button to to reset all features to the default settings.
4. Reset LO TEMP and HI TEMP settings to desired temperatures (see page 7)

Dial

Setting

Feature

Options

Description

Default

Setting

1

Thermal Pre-Purge

OFF

On

Purge Inactive

Purge Active

OFF

2

Fahrenheit or Celsius

F

c

Degrees Fahrenheit

Degrees Celsius

F

3

LWCO Manual or

Automatic Reset

A

b

Automatic Reset

Manual Reset

A

4

Circulator Options

A

b

C

Circulator operation on TT call only

Circulator operation on ZC/ZR call only

Circulator operation on call from either

A

Circulator Hold Off

Circulator Hold Off – Active

Circulator Hold Off – Inactive

Not available

on this control

Not available

on this control

Low Water Cut-Off

Function

Low Water Cut-Off ON

Low Water Cut-Off OFF

dEF

Restore Factory

Defaults

Y

n

Restore Defaults

Do Not Restore Defaults

n

NOTE: If the HydroStat is factory-equipped on a boiler, some options may be set differently from the default settings.

SEE PAGE 7 FOR ADDITIONAL SETTINGS

OPTIONAL FEATURES continued