TROUBLE SHOOTING GUIDE

We don't think you'll ever have to look at this section, but if you do you'll find a quick answer to your question.

SYMPTOM

PROBABLE CAUSE

SOLUTION

Carriage clamping pressure

Carriage clamp not adjusted

Adjust clamping pressure (see page 18).

is too tight or too loose.

properly.

LEXAN

TM

scale is difficult

Scale slot has become dirty.

Remove the scale and clean the slot thoroughly with

to slide

paste wax or, preferably, Top-Cote (available from your
INCRA dealer). Then slide the scale back into the slot.
CAUTION: DO NOT allow wet Top-Cote to come into
contact with LEXAN scale or Templates, or any other
plastic material.

Racks do not mesh properly

Sawdust on racks.

Remove all debris from the racks' teeth with a stiff

when engaging the carriage

brush, such as a toothbrush. (DO NOT attempt to

clamp.

clean the racks with solvents of any kind as this may
damage them.)

Scale mark is not aligned directly

Set the jig to mid-position and lock the carriage clamp.

under the hairline cursor.

Then position the scale so that the 8" mark is directly
under the hairline. When setting the jig to any new
position, always make sure that the scale mark is
aligned directly under the hairline cursor BEFORE
locking the carriage clamp.

Carriage racks are improperly

Realign the carriage racks as described on page 19.

aligned.

When the jig is moved to a

Fence is improperly mounted on

If the fence is mounted too high or too low on the

new position the carriage

the fence bracket.

bracket, it can cause resistance when moving from one

does not glide easily.

position to another. If this is the case, loosen the
screws holding the fence and realign. See page 4,
Step 2.

Surface of table is not flat.

Bumps or dips on the table surface can force the
carriage into non-parallel alignment with the base.
Check your table surface for flatness. This is also
important from a woodworking standpoint because
errors in the surface of the table will translate directly
into errors in your finished work.

Fence is not square to the

Fence is improperly mounted on

If the fence is mounted either too high or too low on the

table surface at all jig

the fence bracket.

fence mounting bracket, it can change the angle of the

positions.

fence relative to the table when it is moved from one
position to another. If this is the case, loosen the
screws holding the fence to the bracket and realign.
See page 4, Step 2.

There are several possible causes:

If you identify any of these, take steps to correct the

Jig mounting board is not flat,

problem. You can also use shims to bring the fence

table is not flat, sawdust between

into perfect squareness as per the instructions on

table and mounting board, or

page 5 of your INCRA PRO Fence System owner's

sawdust between the mounting

manual.

board and the jig.