Johnson Systems DMX 6-PORT MERGER User Manual

Page 20

Advertising
background image

WWW.JOHNSONSYSTEMS.COM

20

3. Open PowerTerm® Lite on the PC.

The “Connect” window automatically pops up when

PowerTerm® is first opened. Alternatively, select the

“Communication” menu tab and click “Connect”. Set “Session

Type” to “COM” and “Terminal Type” to “VT 52”. In the

“Parameters” area, the only important setting is the “Port

Number” (all other settings within the “Parameters” area are

ineffective). Be sure the correct “Port Number” is selected.

If unsure of the “Port Number”, refer to point 7 of the

USB Driver Information section on page 23.

Click “Connect” to continue.

4. On the DMX 6-PORT MERGER, go to menu item

TECHPORT and set to ENABLED. A hybrid USB

symbol appears on the top line of the LCD display

to indicate valid communication between the DMX

6-PORT MERGER and PowerTerm® Lite on the PC.

5. Monitor/view the DMX channel levels received on each of

the DMX input ports, as well as the DMX channel levels

transmitted on the DMX output port. Other diagnostics such

as status, packet size, packet rate can also be viewed.

• Press the “R” key to refresh the screen.

• Press the “1” key to view the DMX input port 1 levels.

• Press the “2” key to view the DMX input port 2 levels.

• Press the “3” key to view the DMX input port 3 levels.

• Press the “4” key to view the DMX input port 4 levels.

• Press the “5” key to view the DMX input port 5 levels.

• Press the “6” key to view the DMX input port 6 levels.

• Press the “7” key to view the DMX output port levels.

• Press the “U” key to toggle the units displayed (Percent,

Hexadecimal or Decimal).

NOTE: For suitable viewing, some setup is required. Refer to the

PowerTerm® Lite Terminal Setup Information section

on page 21 for details.

NOTE: Once viewing is complete, be sure to disconnect from the

session properly as indicated below.

Disconnection Procedure:

6. On the DMX 6-PORT MERGER, go to menu item

TECHPORT and set to DISABLED.

7. On PowerTerm® Lite, select the “Communication” menu tab

and click “Disconnect”.

8. Close PowerTerm® Lite on the PC.

9. Disconnect the USB cable from the Tech Port and PC.

Advertising