background image

HT60-M2 / HT60-M3

31

43

48

49

50

51

55

52

43a

41

Filling

1. Attach a tube at the overflow nozzle (48) and lead it into a

suitable vessel.

2. Remove the screw plugs from the pump connection (50,

51) and connect it to the external system by means of
metal tubes (open end wrench SW19)

3. Remove the screw plug from the connection (43a) and

srew on the expansion tank (43)

4. Always close tightly the connections which have not been

used (e.g. 41 or 52, 53) with screw plugs, the drain plug
(42) is also important.

5. Connect the mains supply (see above) and switch on the

mains switch (1).

6. Fill the unit by pouring the fluid into the expansion tank,

which is connected to the cooling zone.

7. Operate key

Internally a valve opens the passage to the heating zone.
With a reduced no. of rotations the pump motor pumps the
tempering liquid into the externally connected consumer.


8. Slowly refill tempering liquid until two or three segments of the level indication

light up. The necessary quantity of liquid then is in the tempering system.

9. If the minimum level liquid remains under, a low level alarm E01 can be caused.

By a short switching-off and switching-on again at the mains switch (1) the alarm
status is cancelled.

Afterwards again refill the tempering liquid and operate the key

until two or

three segments of the level indication lighten.

10. Operate key

in order to finish the filling process.

Notice

:

• Do not drain the bath fluid while it is hot or cold !

Check the temperature of the bath fluid prior to draining (by switching the unit on for a
short moment, for example).

• Store and dispose the used bath fluid according to the laws for environmental protection.


Draining

1. Cool the fluid below 40C and then turn off the mains switch.

2. Place the circulator to the table edge and put under a suitable vessel to uptake the

used tempering liquid.

3. For emptying unscrew the drain nut (42) on the front of the HT30 and have the

tempering liquid run into a suitable vessel.