Function instructions feature details – Klein Tools CL3200 User Manual

Page 4

Advertising
background image

A.

Use CATIII 1000V or CAT IV 600V rated leads or higher.

Do not attempt to measure more than 1000V DC or 750V AC

B.

Keep hands below line when measuring high current levels.

C.

Auto Power-Off (Apo)

• Device will power off after 30 minutes non-use.

• Turn the dial or press a button to wake.

• Holding HOLD button while turning on disables Auto Power-Off.

D.

Hold / Backlight / Worklight

• Press to hold the current input on the display.

• Press again to return to live reading.

• Press for 2 seconds to enable / disable lights.

• Using lights decreases battery life.

E. F. Battery Replacement

• When

indicator is displayed on the LCD, batteries must be

replaced.

• Remove the back screw and replace 2 x AAA batteries.

G.

Magnetic Back

• Attach instrument to metal for hands-free use.

H.

Bar Graph

• The bar graph shows an approximate analog representation

of a measurement.

• The bar graph responds much faster than the digital display.

• The scale of the bar graph is zero to the maximum reading of

the selected range.

1

2

4
3

5
2

FUNCTION INSTRUCTIONS

FEATURE DETAILS

Advertising