ELECTRICAL SPECIFICATIONS

DC Voltage Measurement

Range

Resolution

Accuracy

1.0V ~ 1000V

0.001V ~ 1V

± (1.0% + 4 digits)

-1.0V ~ -1000V

0.001V ~ 1V

Overload Protection:

1000V

Input Impedance (Nominal): >10MΩ, < 100pF
AC Voltage Measurement

Range

Resolution

Accuracy

1.2V ˜ 750V

0.001 ~ 1V

± (1.5% + 3 digits)

Overload Protection:

750V RMS

Frequency Response:

45 to 400 Hz

Response:

Averaging

Input Impedance (Nominal): >10MΩ, < 100pF
Input Impedance (Low Z) >3kΩ, <200pF, up to 600V RMS
AC Current Measurement

Range

Resolution

Accuracy

0.9A ~ 200A

0.1A

± (2.0% + 8 digits)

Overload Protection:

• Current:

200A

Frequency:

45 to 1kHz

Response:

Averaging

Resistance Measurement

Range

Resolution

Accuracy

400

Ω ˜ 4MΩ

0.1

Ω ˜ 0.001MΩ

± (1.0% + 4 digits)

40M

Ω

0.01M

Ω

± (2.0% + 4 digits)

Overload Protection:

600V RMS

Continuity Test

Overload Protection

Open Circuit Voltage

Threshold (Appx.)

600V RMS

< 0.44V

< 40

Ω

Overload Protection:

600V RMS

Non Contact Voltage Detector

On Voltage

Appx. 25V AC and above

SYMBOLS USED ON LCD

~

AC Measurement

DC Measurement

-

Negative DC Value

AT

Auto Range Active

O.L.

Overload: Range Exceeded

Apo

Auto Power-Off Active

Low Battery

HOLD

Hold Active

V

Voltage Measurement

A

Current in Amps

Ω

Resistance in Ohms

Continuity Test

k

Kilo 10

3

M

Mega 10

6

Advertising