Koolance CTR-CD1224-R User Manual

Page 3

Advertising
background image

6

The Koolance flow meter model number (SKU) will flash. Press

▼ or ▲ to adjust this based

on the following:

• INS-FM16: change to “FM-16”

• INS-FM17, INS-FM17N, INS-FM18, INS-FM19: change to “FM-17”

Press

to move to the next option.

The tubing internal diameter (ID) size will flash. This

refers to the hose size attached to the flow meter itself.

Press

▼ or ▲ to adjust this based

on the following:

• 6mm (1/4 inch): change to “ID: 6mm”

• 10mm (3/8 inch): change to “ID: 10mm”

• 13mm (1/2 inch): change to “ID: 13mm”

Press

to return to the previous menu.

DISPLAY SET

The display settings configure which values you wish to appear on the front display and how
they are shown:

DISPLAY
FIXED

CYCLIC : Show 2 values or cycle multiple values

The first option, “FIXED”, will flash. Press

◄ or ►

to change between these options. Press

to configure one of the selections, or press

▲ to exit.

If “FIXED” is selected, two lines will

be shown:

TEMP1 21.7C : First line display option
TEMP1 21.7C : Second line display option

The first line will flash. Press

▼ or ▲ to change what this line will display:

TEMP1 21.7C : Show temperature sensor #1
TEMP2 21.2C : Show temperature sensor #2
TEMP3 20.8C : Show temperature sensor #3
FAN1

1770RPM : Show fan channel #1

FAN2

1640RPM : Show fan channel #2

FAN3

1820RPM : Show fan channel #3

PUMP

5730RPM : Show pump speed

FLOW

4.1LPM: Show flow rate

Press

to confirm. The second line will flash. Press

▼ or ▲ to adjust this line.

Press

◄ to return to the previous menu, or press

to return to the main screen.

When “FIXED” is the chosen display option, line 1 and 2 can be changed quickly without
reentering the DISPLAY SET menu. To do this, briefly press

from the main screen. The

first line will flash:

TEMP1 21.7C : First line display option
PUMP 5400RPM : Second line display option

Instead of manual speeds, fans can also be set to automatic. This is highly recommended,
since speeds will change based on temperature sensor feedback. This is a good way to keep
noise levels to a minimum while allowing the cooling system to respond to temperature. To
set a fan channel to automatic, press

▲ past 100% until “AUTO” is shown:

ALL FANS

AUTO

From here, press

to configure the automatic mode:

ALL FANS

AUTO

T1 L45C

H80C : Temp Sensor, Low Point, High Point

The number following “T” designates the temperature sensor this fan channel will follow.
When flashing, press

▼ or ▲ to change sensors (1-3).

Press

to move to the next

option.

The number following “L” is the temperature low point. The number following “H” is the
temperature high point. Automatic fan control will adjust fans on a dynamic ramp between
these two points:

When the temperature low point is flashing, press

▼ or ▲ to adjust it.

Press

to move to

the temperature high point, and press

▼ or ▲ to adjust it. Press

again to return to the

previous menu.

PUMP SET

The pump speed can be manually set from 1-10:

PUMP(1-10) 7LV : Pump Speed Level

The pump speed level will flash. Press

▼ or ▲ to adjust.

Press

to return to the previous

menu.

FLOW SET

If a Koolance flow meter (sold separately) has been connected to the unit, configuration is
needed to properly display its values. Only one flow meter can be displayed by the cooling
system.

FLOW METER SET
FM-17 ID: 10mm : Flow Meter Model, Tubing Internal Diameter

20%

100%

45ºC

(Low Point)

80ºC

(High Point)

Automatic Fan

Power

5

Advertising