7

Press

▼ or ▲ to change what this line will display among the options described earlier.

Press

to move to line 2, and similarly use

▼ or ▲. Press

again to exit.

If “CYCLIC” is chosen from the DISPLAY SET menu, multiple values will be rotated through

the front display. The first option is whether these values will cycle vertically or horizontally
through the display:

CYCLIC
VERT HORI: Scroll values vertically or horizontally

The first option, “VERT”, will flash. Press

◄ or ►

to change between these options, press

to configure a selection, or press

▲ to exit.

Choosing either option with

will list all

available values:

*TEMP1 21.7C : Show temperature sensor #1
*TEMP2 21.2C : Show temperature sensor #2
*TEMP3 20.8C : Show temperature sensor #3
*FAN1 1770RPM : Show fan channel #1
*FAN2 1640RPM : Show fan channel #2
*FAN3 1820RPM : Show fan channel #3
*PUMP 5730RPM : Show pump speed
*FLOW 4.1LPM: Show flow rate

The selected line will flash. Use

▼ and ▲

to navigate to other lines. Press

to enable or

disable each value. This will remove the asterisk, thereby hiding that line from being shown
on the main screen:

*TEMP1 21.7C : (shown)
*TEMP2 21.2C : (shown)

*

TEMP3 20.8C : (not shown)

*FAN1 1770RPM : (shown)

*

FAN2 1640RPM : (not shown)

*

FAN3 1820RPM : (not shown)

*PUMP 5730RPM : (shown)
*FLOW 4.1LPM: (shown)

Press

to return to the previous menu, or press

to exit DISPLAY SET.

This page is intentionally left blank.

Temperature Sensor Placement

Three surface temperature sensors are included
with this product for monitoring. Generally,
sensors are affixed to water blocks with metal tape.
(Liquid temperature sensors are also available
optionally from Koolance.)

Sensors should never be placed directly
between a heat source and its water block. This
will interfere with contact and can damage the
sensor or heat source.

Chip contact

area

(keep out)

Advertising