16

17

User Manual

Nozzles are designed to attach tightly. If you need to remove a hose for any reason,
it may not pull off easily, even after unscrewing the compression fitting.

Usually, a connection will come free by squeezing the hose on top of the nozzle
and pulling away. If this fails, cutting a small incision lengthwise (parallel) along the
nozzle should free it.

When a hose has been removed, it may have distorted the tubing beneath it. This
last portion (about 1cm, 7/16”) should be trimmed to ensure a perfect fit with the
next connection.

The tip should always be re-cut if you needed to remove the tubing with an
incision.

Connecting ERM Systems

Disconnecting Hoses

Hose Lengths

Before installing your liquid coolers, appropriate lengths of tubing must be cut to
connect each device. It is generally easier to estimate the required tubing amounts
with installed computer hardware.

On the rear of the ERM, the inlet and
outlet nozzles are labeled. Generally,
the outlet will connect first with your
CPU Cooler.

With the connected outlet
hose, roughly estimate the
length you will need to your
first cooler, and cut it.

Cut the second hose with
enough length to connect
with the last cooler that will
be in your system.

Using the leftover tubing, cut
shorter pieces to link between
each individual cooler.

Coolant Outlet