Bunn TNTF-3 User Manual

Page 20

Advertising
background image

Page 20

Location:

The iced tea brew timer is located in the hood on

the right side. It consists of the dial plate and circuit
board.

Test Procedure:
1. Disconnect the brewer from the power source.
2. Remove the wires from terminals TL3, TL4, & TL5

of the iced tea timer and rotate the dial fully coun-
terclockwise.

2. With a voltmeter, check the voltage across termi-

nals TL1 and TL2 when the ICED/OFF/HOT switch
is in the “ICED” position. Connect the brewer to
the power source. The indication must be 120
volts ac for two wire 120 volt models and three
wire 120/208 volt models.

3. Disconnect the brewer from the power source.

If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the

Wir-

ing Diagram

and check the wiring harness.

4. Check for continuity across the orange and yel-

low wires when the start switch is held in the lower
position.

If continuity is present as described, reconnect the
wires to terminals TL3, TL4, & TL5 of the timer board
and proceed to #5.
If continuity is not present as described, refer to the

Wiring Diagram

and check the wiring harness.

5. With a voltmeter, check the voltage across termi-

nals TL1 and TL4 when the ICED/OFF/HOT switch
is in the “ICED” position and the start switch is
momentarily placed in the lower position. Con-
nect the brewer to the power source. The indica-
tion must be 120 volts ac for two wire 120 volt
models and three wire 120/208 volt models for
approximately twenty seconds and then return to
its previous indication.

6. Disconnect the brewer from the power source.

If voltage is present as described, the timer is operat-
ing properly. Adjust the timer dial as required.
If voltage is not present as described, replace the timer.

Removal and Replacement:
1. Remove all wires from the iced tea brew timer.
2. Remove the circuit board and dial plate from the

brackets.

3. Install the new timer circuit board as described in

Late Model Timer

section on the following pages.

4. Refer to Fig. 13 when reconnecting the wires.
5. Install the Timer Setting Decal, provided with the

timer replacement kit, on the bottom of the hood
cover.

6. Adjust the timer as required. See

Late Model Timer

Section

on the following pages.

FIG. 11 ICED TEA BREW TIMER TERMINALS

P1365.85

FIG. 10 ICED TEA BREW TIMER

P1391.60

SERVICE (cont.)

BREW TIMER (ICED TEA - EARLY MODELS)

28201 081500

OLD STYLE

OLD STYLE

ORN to Start Switch
WHI/BLU to Iced Tea
Brew Solenoid
YEL to Start Switch

WHI/RED to Hot Tea Brew Solenoid
WHI/RED to ICED/OFF/HOT Switch

WHI to Power Cord (120V Models)
or WHI to Terminal Block 120/208V
Models)

Advertising
This manual is related to the following products: