Technical data, General data and operating conditions – Lenze 8400 BaseLine Manual User Manual

Page 21

Advertising
background image

Technical data

General data and operating conditions

4

21

EDS84ABD302 EN 4.0

Environmental conditions
Climate

Storage

IEC/EN 60721-3-1

1K3 (-25 ... +60 °C)

Transport

IEC/EN 60721-3-2

2K3 (-25 ... +70 °C)

Operation

IEC/EN 60721-3-3

3K3 (-10 ... +55 °C)

Operation at 2/4 kHz, +45 ... +55 °C:

Operation at 8/16 kHz, +40 ... +55 °C:

For operation above +40 ... +45°C, reduce rated output

current by 2.5 %/°C

Site altitude

0 ... 4000 m amsl

1000 ... 4000 m amsl:

Reduce rated output current by 5 %/1000 m

2000 ... 4000 m amsl: overvoltage category II

Pollution

EN 61800-5-1

Pollution Degree 2

Vibration resistance

(9.81 m/s

2

= 1 g)

Transport

IEC/EN 60721-3-2

2M2

EN 61800-5-1

2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s

2

200 ... 500 Hz: acceleration resistant up to 15 m/s

2

Operation

Germanischer Lloyd

5 ... 13,2 Hz: amplitude ±1 mm

13.2 ... 100 Hz: acceleration resistant up to 0.7 g

EN 61800-5-1

10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 10 m/s

2

(1 g)

Requirements on the motor cable
Capacitance per unit length

1.5 mm

2

/AWG 16

C

Core/core

/C

Core/shield

75/150 pF/m

2.5 mm

2

/AWG 12

C

core/core

/C

Core/shield

100/≤ 150 pF/m

Electric strength

VDE 0250-1

U

0

/U

=

0.6/1.0 kV

(U

0

= r.m.s. value - external conductor to PE,

U = r.m.s. value - external conductor to external conductor)

UL

U ≥ 600 V

(U = r.m.s. value - external conductor to external conductor)

Advertising