Mechanical installation

Standard devices in the power range 1.5 ... 2.2 kW

EDK82ZJ003 DE/EN/FR 1.0

11

l

−H2−M_INST_TS_Mo_BL_751

Mounting

1.

1.

2.

3.

3.

4.

5.

E82DV_002

1. Slide on frame.
2. Insert seal.
3. Slide earthing clamps on the frame with the correct sides:

– The contact springs have to point towards the rear panel of the control cabinet.
– The cutouts of the seal specify the positions.

4. Insert 8200 vector into cutout.
5. Tighten by means of 8 screws M4x10.

– Tightening torque: 1.7 Nm (15 lb−in)