Mechanical installation – Lenze E82ZJ00x User Manual

Page 9

Advertising
background image

Mechanical installation

Standard devices in the power range 0.25 ... 0.75 kW

EDK82ZJ003 DE/EN/FR 1.0

9

l

H1_MechINS−M_INST_TS_Mo_BL_751

Mounting

3.

3.

2.

1.

1.

4.

5.

E82DV_001

1. Slide on frame.
2. Insert seal.
3. Slide earthing clamps on the frame with the correct sides:

– The contact springs have to point towards the rear panel of the control cabinet.
– The cutouts of the seal specify the positions.

4. Insert 8200 vector into cutout.
5. Tighten by means of 8 screws M4x10.

– Tightening torque: 1.7 Nm (15 lb−in)

Advertising