TROUBLESHOOTING

FUNCTION

SYMPTOM

POSSIBLE CAUSE

REMEDY

3.30

Excessive

Noise while

Ramp

Stowing

3.20

Ratcheting

Noise at End

or during

Ramp Stowing

Remove object from mat.

See controller diagnostic guide

Check ramp for obstructions.

Check ramp for excessive debris

contamination inside cassette

Check adjustment or replace

Adjust chain

Clean debris from cassette

3. Pressure mat activated

3.2 Obstruction sensing activated

3.2 Ramp full in limit switch defective

3.3 Lose chain

3.32 Debris inside ramp cassette

2.10

Ramp Starts

to Deploy

then Stops

2.00

DEPLOY

OPERATION

2.30

Excessive

Noise during

Ramp

Deployment

2.20

Ratcheting

Noise at End

or during

Ramp

Deployment

Remove object from mat.

See controller diagnostic guide

Check ramp for obstructions.

Check ramp for excessive debris

contamination inside cassette

Check adjustment or replace

Adjust chain

Clean debris from cassette

2. Pressure mat activated

2.2 Obstruction sensing activated

2.2 Ramp OUT-Limit microswitch is out

of adjustment or defective

2.3 Loose chain

2.32 Debris inside ramp cassette

3.10

Ramp Starts

to Stow

then Stops

3.00

STOW

OPERATION

Advertising