6 error codes, Error codes, Api functions 3 – Lenze 3241C User Manual

Page 25

Advertising
background image

API

functions

3

23

3.5

Status description of the backplane bus (state machine)
The switch-on procedure in the backplane bus is effected in several steps.

Status

Transition

Description

1.

Init

Initialisation of the peripherals, automatic transition to
the PreOperational state, and setting a status bit.

No PDO & SDO communication

2.

PreOperational

SDO communication possible

- Reception of configuration data for the individual

terminals

- Waiting for the "Start“ telegram, or repeated "Config“
L-force Controller -> BPB controller

- Transmission of the terminal data to the IPC

3. Operational

SDO & PDO communication possible

3.6

Error codes
The programming interface returns the following possible error codes. Errors are
returned as a bit mask, i.e. several error codes can be linked with each other in each
case.
Error list for the status register
(Error byte in the status register)

Error number

Category

Source

Description

Dec Hex

0

0

-

-

No error; ok

11 B Warning

BPB

controller

Synchronisation: DPRAM lock register

12

C

Warning

BPB controller Result FIFO full

31 1F Warning BPB

driver

Synchronisation: DPRAM lock register

32

20

Warning

BPB driver

Timeout: Reset

33

21

Warning

BPB driver

Timeout: ErrorReset

96

60

Error

BPB controller Error during creation of group 1

97 61 Error BPB

controller Error during creation of group 2

98

62

Error

BPB controller Error during creation of group 3

99

63

Error

BPB controller Groups ok, but cycle time not sufficient

100

64

Error

BPB controller Error during processing the master queues

Advertising