Mag.layers – Mag Layers USA MCI-2012 User Manual

Page 4

Advertising
background image

Temperature : +85

±2℃

Applied voltage : Rated voltage

Applied current : Rated current

Testing time : 500

±12 hours

Measurement :After placing for 24 hours min.

Temperature : +85

±2℃

Humidity : 90 to 95%RH

Applied current : Rated current

Applied voltage : Rated voltage

Testing time : 500

±12 hours

Measurement :After placing for 24 hours min.

Temperature : -25℃,+85℃

kept stabilized for 30 minutes each.

Cycle : 100 cycle

Measurement :After placing for 24 hours min.

Low

Temperature : -25

±2℃

temperature

Testing time : 500

±12 hours

Storage

Measurement :After placing for 24 hours min.

Frequency : 10 to 50 Hz

Amplitude : 1.52 mm

Dimension and times : X ,Y and Z directions

for 2 hours each.

MCI-2012-SERIES

Page-4/7

Item

Specifications

Test conditions

Vibration

Appearance : Ferrite shall not be
damaged.

High
temperature

Appearance : Ferrite shall not be
damaged.
Impedance:Within

±20% of the

initial value.
insulation resistance: >10(M

Ω)

DC resistance : standard value
inside.

Humidity
resistance

Thermal shock

MAG.LAYERS

-40℃

+85℃

30 min.

30 min.

1 cycle

30 sec

Advertising