DEPTH ADJUSTMENT

SCREWS

WALL FRAMING

MOUNTING

SCREWS

(4.8x38mm)

RECTANGULAR CUTOUTS

MOUNTING
BRACKETS

HEIGHT

ADJUSTMENT

SCREWS

MOUNTING

SCREWS

(4.8x38mm)

INSTALL THE HOOD

3. Remove the tape located on the damper.

4. Hang the hood from the brackets through

the rectangular cut-outs on the back of the

hood. Cut-outs are larger than the brackets

to allow for horizontal adjustment.

The bottom of the hood should be 24" to 30"

above the cooking surface.

5. Height adjustment screws provide vertical

adjustment.

6. Depth adjustment screws provide

horizontal adjustment.

7. Secure the hood with mounting screws

(4.8x38mm). Use drywall anchors, provided,

if wall studs or framing are not available.

REMOVE THE TAPE

WIRING

Note: This range hood must be properly

grounded. The unit should be installed by a

qualified electrician in accordance with all

applicable national and local electrical codes.

1. Remove the wiring box cover. Remove a

knockout from the wiring box.

2. Secure the conduit to the wiring box

through a conduit connector.

3. Make electrical connections. Connect white

to white, black to black and green to green.

4. Replace wiring box cover and screws. Make

sure that wires are not pinched between

cover and box.

DUCT

COLLAR

WIRING BOX

COVER