6" ROUND

METAL DUCT

DECORATIVE

FLUE

DUCT TAPE

AIR VENT

POSITION FOR

DUCTED

CONFIGURATION

CONNECT DUCTWORK

Ducted Configuration
1. Use (2) screws (4.8x38mm) and wall

anchors to secure upper bracket to the

ceiling or wall as shown.

2. Use 6" round metal duct to connect the duct

collar on the hood to the ductwork above.

3. Use duct tape to make all joints secure and

air tight.

4. Remove the 2 screws securing the flues.
5. Connect the upper section of decorative flue

to the bracket with screws provided

(3.2x13mm).

6. Slide the lower section of decorative flue

downward, until it fits properly around hood.

7. Secure decorative flue to hood with screws

provided (3.2x13mm).

FASTEN

FLUE TO

HOOD & UPPER

BRACKET WITH

SCREWS

(3.2x13mm)

FLUE MOUNTING

BRACKET

MOUNTING

SCREWS

(4,8x38mm)

FIXING TO THE WALL

FIXING TO THE CEILING

FLUE MOUNTING

BRACKET

MOUNTING

SCREWS

(4,8x38mm)