DOOR ALIGNMENT

Figure 5

Hinge adapter bracket lo-

cated on the top and bottom

of the door.

Remove top

hinge pin to re-

move the door.

Door must be

parallel to top

and sides of

refrigerator.

9/32”

(7.1mm)

NOTE

6

For the door to close properly, it is necessary to maintain a

minimum space of 9/32” (7mm) between the door and cabinet

flange (See Figure 5). This space can be adjusted by adjusting the

top and bottom hinge adapter brackets.

Door Alignment Procedure

The door should be parallel to the sides and top of the refrig-

erator. If alignment is necessary the door may be adjusted by

loosening the 2 screws which secure the hinge adapter brackets

on the top and bottom of the door and adjusting the door side

to side. Use a 5/32” allen wrench for this procedure. (See Figure

5 below). When finished aligning the door, tighten the screws

securely.