INSTALLING THE DRAIN PLUMBING

Drain Plumbing

Your ice machine uses a gravity drain (Figure 4) that requires

5/8” inside diameter (I.D.) tubing from the back of the ice

machine to a plumbed connection to a sanitary sewer. Remove

the access panel to plumb in drain connection. Gravity drain

location for built-in units can be within the area shown in Figure

6. An optional drain pump (Figure 5) can be purchased for your

ice machine if a gravity drain is not accessible. See page 6 for

optional drain pump installation.

Observe and follow all local codes when installing ice machine.

Figure 3

• Do not splash or spray water from a hose on the ice ma-

chine. Doing so may cause an electrical shock, which may

result in severe injury or death.

• This unit should not, under any circumstances, be installed

to an un-grounded electrical supply.

Grounding Method

This product is factory equipped with a power supply cord that

has a three-pronged, grounded plug. It must be plugged into a

mating grounding type receptacle in accordance with the Na-

tional Electrical Code and applicable local codes and ordinances

(see Figure 3). If the circuit does not have a grounding type re-

ceptacle, it is the responsibility and obligation of the customer to

provide the proper power supply. The third ground prong should

not, under any circumstances, be cut or removed.

Electrical Connection

A 115 volt, 15 amp dedicated circuit is required. A 3 prong

grounded receptacle is required.

The unit must be installed according to your local building codes

and ordinances.

Do not use an extension cord with

this appliance.

Drain

Access

Figure 6

Figure 5

Figure 4

Failure to use adequate drainage system will result in surround-

ing water damage and/or poor ice production.