Optional drain pump installation – MARVEL Scientific 6ADi User Manual

Page 7

Advertising
background image

30CM Installation

1. Turn the ice machine to gain access to the rear of the unit.

Remove the access panel by removing the ten (10) screws

(see Figure 7).

2. Plug the ice machine’s power plug into the outlet on the

drain pump. Place the drain pump in the left, rear opening

of the ice machine with the inlet, vent, and discharge fittings

to the rear of the unit (see Figure 8).

3. Install 1-3/4 in. x 5/8 in. I.D. inlet tubing to drain barb on ice

machine and then on the inlet of the drain pump. Clamp

both ends of the tube with the large tubing clamps.

4. Connect the 18 in. x 3/8 in. I.D. formed vent tube to the vent

on the drain pump and secure with one (1) of the small tub-

ing clamps.

5. Route a short section of the 20 ft. x 3/8 in. I.D. tube through

the opening in the access panel and connect it to the

discharge of the drain pump. Secure with the small tubing

clamp.

6. Route the vent tube and the drain pump power cord

through the remaining openings in the access panel as

shown in Figure 9. Reinstall the panel and secure.

7. Secure the vent tube to the back of the ice machine using

the supplied tubing clips and screws as shown in Figure 9.

The vent tube must be attached and secured or water damage

may occur. Make certain there are no kinks in the tube. The

drain pump will not operate correctly with a partially blocked

vent line.

8. Connect the discharge tube to a suitable drain. Cut excess

tubing as needed. Do NOT allow sags or kinks in the tubing

that will restrict flow.

9. Make certain that the drain pump is level in the ice ma-

chine’s rear opening.

10. Plug the power cord of the drain pump into a properly

grounded 115VAC receptacle.

11. Test the drain pump by slowly pouring water into the ice ma-

chine ice storage bin. Approximately one (1) quart of water

is required to activate the drain pump.

12. Test the operation of the safety switch by turning the ice

machine on and completely restricting the discharge line

while the pump is operating. Pour more water into the ice

machine’s ice storage bin until the ice machine turns off.

The drain pump will continue to operate. Remove the dis-

charge tube restriction and allow the water to be pumped

out. The power to the ice machine will be restored when

the water in the pump returns to normal.

13. Place the ice machine in the installed location. Ensure

that all tubing and power cords are not pinched, kinked, or

disturbed.

Figure 7

Figure 8

Receptacle for Ice

Machine’s Plug

Towards the Rear of

the Ice Machine

To Wall Receptacle

Inlet Tube

Fitting
Discharge

Tube Fitting

Vent Tube

Fitting

Access Panel

Figure 9

Vent Tube

Drain Pump’s

Power Cord

Access Panel

Screws

Tubing Clips

To Drain

OPTIONAL DRAIN PUMP INSTALLATION

NOTE

Screws

7