Restoring the Factory Settings (Factory Reset)

Restoring the RC-300’s system settings (System parameters) to their

original factory default settings is referred to as “Factory Reset.”
Factory Reset will return the system settings to their factory-set

state, and will erase (initialize) all phrase memories.

* This device contains demo data (Phrase Memory 90–99).

When you erase (initialize) all phrase memories, the demo

data will also be erased and cannot be recovered. Please

back them up as described in “Recovering backed-up data

from your computer to the RC-300” (p. 37).

* If the display indicates “Data Damaged!” and the RC-300 no

longer operates correctly, initialize the RC-300 by choosing

“SYSTEM + MEMORY” in the following procedure.

1.

Turn off the RC-300’s power .

2.

While holding down the [WRITE] and [EXIT] buttons, turn
on the power .

The Factory Reset range setting screen appears in the display.

Factory Reset

SYSTEM + MEMORY

3.

Use the [MEMORY/VALUE] knob to specify the settings

that will be returned to their factory-set state .

Value

Explanation

SYSTEM +

MEMORY

The system settings will be returned to their factory-set

state, and all phrase memories will be erased (initialized)

SYSTEM

The system settings will be returned to their factory-set

state

MEMORY

All phrase memories will be erased (initialized)

* If you execute “SYSTEM + MEMORY” or “MEMORY,” all of the

RC-300’s phrase memories will be erased, and cannot be

recovered.

4.

If you want to proceed with the factory reset, press the

[WRITE] button .

5.

Once “Completed!” appears in the display, you can turn off

the power .

Adjusting the Expression Pedal

Although the RC-300’s [EXP 1] pedal is adjusted for optimal performance when shipped from the factory, extended use over

time and under certain usage conditions may result in the pedal going out of adjustment. If you find the pedal exhibiting

problems, such as “if you’re unable to obtain the minimum value or the maximum value,” you can readjust the pedal using the

following procedure.

1.

Hold down the [SYSTEM] button and switch on the power .

2.

When “EXP1:Set to MIN” is displayed, rock the [EXP 1] pedal all the way back (so that the toe end of the pedal is raised) . Release

your foot from the [EXP 1] pedal, and then press the [WRITE] button .

EXP1:Set to MIN

Press [WRITE]

3.

When “EXP1:Set to MAX” is displayed, rock the [EXP 1] pedal fully forward (so that the heel end of the pedal is raised) . Release

your foot from the [EXP 1] pedal, and then press the [WRITE] button .

EXP1:Set to MAX

Press [WRITE]

4.

When the message “Complete!” appears in the display, switch off the power .