WIRING

CAUTION: All electrical wiring should

be done by a qualified person (s) in

accordance with all applicable codes and

standards. This range hood must be

properly grounded.

Do not turn power on at service panel until

all wires have been connected.

Blower connection at hood:

1. Run 2-wire plus ground power cable from

the Exterior or In-Line Blower to the hood’s

wiring box marked “motor connection”.

2. Remove the cover from the wiring box and

remove one knockout.

3. Secure the conduit to the wiring box through

a conduit connector.

4. Make electrical connections at the hood.

Connect white-to-white, red-to-black and

green-to-ground.

5. Replace the wiring box cover and screws.

make sure wires are not pinched between

the cover and box.

Exterior or In-line blower connection:
1. Make electrical connections at the exterior

or in-line blower (see instructions provided

with the exterior or in-line blower).

Power connection at hood:

1. Run 120 VAC electrical power cable to the

hood wiring box marked “120VAC input”.

2. Remove the cover from the wiring box and

remove one knockout.

3. Secure the conduit to the wiring box through

a conduit connector.

4. Make electrical connections at the hood.

Connect white-to-white, black-to-black

and green-to-ground.

5. Replace the wiring box cover and screws.

Make sure wires are not pinched between

the cover and box.

BLOWER CONNECTION AT

HOOD

BOX MARKED

“MOTOR

CONNECTION”

!

CONNECT: WHITE-TO-WHITE,

RED-TO-BLACK,

GREEN-TO-GROUND.

BOX MARKED

“120 VAC INPUT”

POWER CONNECTION AT HOOD

CONNECT:

WHITE-TO-WHITE,

BLACK-TO-BLACK,

GREEN-TO-GROUND.

120 Volt 60Hz

LINE-IN

Exterior or

In-Line blower