Tl-17 s, C 12" coverage – Metal Sales TL-21 User Manual

Page 6

Advertising
background image

PF/I-6

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

F

lush

F

ace

/ I

nterIor

l

Iner

s

erIes

Tl-17 s

eCTion

P

roPerTies

and

l

oad

T

ables

1

1

/

2

"

C

12" Coverage

1. Theoretical section properties have been calculated per AISI 2001 “Specification for the Design of Cold-formed Steel Structural Members.” Ixx and Sxx are

effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear, deflection, and panel

testing. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or fasteners/support

connection or panel disengagement. Panel weight is not considered.

3. Deflection is limited to L/180.

4. Allowable loads do not include a 1/3 stress increase.

ALLOWABLE UNIFORM LOADS PSF

(3 or More Equal Spans)

2’ 3’ 4’ 5’ 6’ 8’ 2’ 3’ 4’ 5’ 6’ 8’

SECTION PROPERTIES

Bottom in Compression

Width

(in.)

Yield

KSI

12”

50

12”

50

12”

33

12”

33

24

Ga.

22
20
18

Sxx

In

3

/ft

Ixx

In

4

/ft

Weight

PSF

1.34
1.77
2.10
2.76

Top in Compression

Sxx

In

3

/ft

Ixx

In

4

/ft

0.0495

0.0562

0.0746

0.0597 302 145 84 54 38 22 288 137 79 51 36 20

0.0724

0.0860 0.1025

0.0821 409

197 115 75 52 30 29 29 29 29 0 0

0.0986

0.1268 0.1294

0.1043 335

163 95 62 44 25 29 29 29 29 0 0

0.1480

0.1805 0.1790

0.1446 453

224

131 86 60 134 29 29 29 29 0 0

Inward Load

Outward Load

Substructure

Coverage

Length

Fasteners

Availability

GENERAL INFORMATION

ATTACHMENT DETAIL

TL-17 panels are designed to be utilized over open

structural framing or a solid substrate.

TL-17 panels are available in a 1

1

/

2

" depth with a 12" width

coverage.

Minimum factory cut length is 5'-0".

Maximum available panel length is 22'-0".

The fastener selection guide should be consulted for

choosing the proper fastener for specific applications.

Quantity and type of fastener must meet necessary loading

and code requirements.

NOTE: All panels are subject to surface distortion due to

improperly applied fasteners. Overdriven fasteners will

cause stress and induce oil canning across the face of the

panel at or near the point of attachment.

Finishes: Kynar 500 (PVDF) standard; optional: multi-pass

Kynar 500, Marblique, Plastisol, and Polyester

Gauges: 24ga, 22ga, 20ga, and 18ga

*Pre-drilling into thicker steel may be required.

Field-Applied Sealant

#10-12 x 1" Pancake Head Woodscrew

(wood substrate)

or

#10-16 x 1" Pancake Head Driller

(steel substrate)*

FASTENING PATTERNS

#10-12 x 1" Pancake Head Woodscrew

(wood substrate)

or

#10-16 x 1" Pancake Head Driller

(steel substrate)*

Field-Applied Sealant

Advertising
This manual is related to the following products: