Tl-21 s – Metal Sales TL-21 User Manual

Page 7

Advertising
background image

PF/I-7

F

lush

F

ace

/ I

nterIor

l

Iner

s

erIes

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

Tl-21 s

eCTion

P

roPerTies

and

l

oad

T

ables

16" Coverage

3"

7

/

8

"

2

15

/

16

"

1

1

/

4

"

11

/

16

"

NOTE: Either side of panel can be painted, please specify

ALLOWABLE UNIFORM LIVE LOADS PSF

(3 or More Equal Spans)

4' 5' 6' 7' 8' 9' 4' 5' 6' 7' 8' 9'

SECTION PROPERTIES

Bottom in Compression

Width

(in.)

Yield

KSI

16"

50

16"

50

16"

33

16"

33

24

Ga.

22
20
18

Sxx

In

3

/ft

Ixx

In

4

/ft

Weight

PSF

1.38
1.82
2.22
2.93

Top in Compression

Sxx

In

3

/ft

Ixx

In

4

/ft

0.3158

0.1244

0.1883

0.1100 130 89 64 49 38 30 141 97 71 54 42 34

0.4838

0.1972

0.2708

0.1667 219 145 103 77 59 47 250 168 120 89 69 55

0.7050

0.3005

0.3720

0.2447 223 145 102 76 58 46 266 175 124 92 71 59

0.9488

0.4070

0.5438

0.3431 312 204 143 106 81 65 363 238 168 125 96 76

Inward (Gravity / Deflection)

Load

Outward Uplift (Stress)

Load

1. Section properties and allowable loads are calculated per AISI 2001, including 2004 Supplement.

2. Ixx and Sxx are effective section properties for deflection and bending.

3. Allowable loads/spans are calculated considering bending, shear, combined bending and shear and deflection.

4. Allowable load/span calculations do not include consideration for web crippling, fastener / connection limitations or uplift testing.

5. Allowable loads/spans do not include a 1/3 stress increase.

Substructure

Coverage

Length

Fasteners

Availability

GENERAL INFORMATION

TL-21 Panels are designed to be utilized over open structural

framing or a solid substrate.

TL-21 Panels are available in a 3" depth with a 16" width

coverage.

Minimum factory cut length is 5'-0".

Maximum available panel length is 32'-0".

The fastener selection guide should be consulted for choos-

ing the proper fastener for specific applications. Quantity

and type of fastener must meet necessary loading and code

requirements.

NOTE: All panels are subject to surface distortion due to

improperly applied fasteners. Overdriven fasteners will

cause stress and induce oil canning across the face of the

panel at or near the point of attachment.

Finishes: Kynar 500 (PVDF) standard; optional: multi-pass

Kynar, Marblique, Plastisol, Polyester, and

MS Colorfast45

®

(SMP)

Gauges: 24ga, 22ga, 20ga, and 18ga

#12-14 x 1

1

/

4

" Self Driller

ATTACHMENT DETAIL

#12-14 x 1

1

/

4

" Self Driller

FASTENING PATTERN

Ends and Field of Panel

Advertising