6. Cooling Flow: Maintenance/Troubleshooting:

Verify the cooling flow by

ensuring Adjusting Clamp is

open. Remove the Cooling

Transfer Tube from the coupling.

Place Pump into a bucket of

water and check flow.

Remove the Cooling Transfer

Tube and check for flow.

Remove the Pump Discharge

Fitting and check for flow.

Remove the Pump Intake

Screen and check for debris–

clean the screen if necessary.

Remove the 3 Pump Casing

Retaining Screws.

Remove the Pump Casing and

check for restriction in the

casing. Check the Impeller for

damage.

© 2010 MK Diamond Products, Inc. All Rights Reserved. Images and specifications are subject to change without notice. Part # 164800-IS (03/10)

1315 Storm Parkway, Torrance, CA 90501

|

P 800.421.5830

|

www.mkdiamond.com

|

F 310.539.5158

Remove the Drain Plug from

the water pan.

Place the Water Pump in an

external container. Fill the external

container until water completely

covers the Water Pump suction.

4. External Water Source:

Place an external catch basin

below the water pan drain hole.