MANTA IV Core Drill Technical Data

Diamond Drilling Unit

MANTA IV

Nominal Voltage

110/120 V ~

Rated Current

18 Amp.

Frequency

0-60 Hz

No-Load Speed

700 rpm

Max. Drilling Diameter

6 inch.

Collet

1 1/” UNC

Net Weight

About 1. kg

TABLE 1

Technical data for the MANTA IV is listed in TABLE 1.

Electrical Connections

For protection purposes the machine can only be operated when used with a GFCI. The machine is

standard equipped with a GFCI switch in the cord which allows connecting the unit direct to a grounded

socket.

Attention!

The GFCI protective switch must not come in contact with water.

GFCI protective switches must not be used to switch the tool ON and OFF.

Check for proper function by pressing the TEST button before starting your work.

Use only three-wire extension cord with ground wire of sufficient gage. The usage of a smaller wire could

lead to excessive overheating of the motor and the cable.

Connect the tool to the water supply system or a water pressure vessel.

Attention! The maximum water pressure should not be more than  psi. Always make sure that the

machine runs with enough water, as the seals can be damaged when running dry. This could lead to

leakage of water into the gearbox housing.

Water Connections

The MANTA IV is equipped with a mechanical and electronic overload protection. This is designed to

protect the operator, the motor and the drill bit.

Mechanical: If the drill bit is suddenly blocked, a clutch will slip to disengage the bit from the motor.

Electronic:

In case of overload due to a large feed force, the motor will be automatically switched off.

After discharge, switch OFF and ON again and drilling can be continued.

Overload Protection

Set Up and Operating Instructions

Extension Cord Minimum Gage for Length

Volts

Total Length of Cord in Feet

120 V

25

50

100

150

AWG

AWG

AWG

AWG

1

12

Not Recommended

TABLE 2