Mixer Troubleshooting

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

Drum rotates rough

Defective ring gear?

Check that the ring gear and bearings are

not worn. Replace as necessary.

Defective pinion gear?

Check that the pinion gear and bearings

are not worn. Replace as necessary.

Worn V-belt?

Replace V-Belt.

Loose pulley?

Tighten or replace pulley.

Drum does not

rotate at all

Fuel?

Check level of fuel in fuel tank. Add fuel if

necessary. Make sure fuel is being supplied

to the engine. Check to ensure that the fuel

filter is not clogged.

Broken V-belt?

Replace V-belt.

Defective ring or pinion gears?

Check that the gears and bearings are not

broken. Replace as necessary.