Wiring and battery, Ab c d – MotorGuide Saltwater User Manual

Page 20

Advertising
background image

WIRING AND BATTERY

16

eng

Connect the black battery lead from the power cable to the negative (–)

post on battery A and the red lead to the positive (+) post on battery B.

Connect a jumper wire between the negative (–) post of battery B and

the positive (+) post of battery A. Install a 50 amp circuit breaker in line

with the positive lead to battery B, as shown.

24 volt battery hookup

a -

Power cable

b -

50 amp manual reset circuit breaker

c -

Jumper wire

d -

Common ground

RED

BLK

a

b

c

d

37824

GRY

c

Battery A

Battery B

Advertising