Owner service assistance – MotorGuide Saltwater User Manual

Page 39

Advertising
background image

OWNER SERVICE ASSISTANCE

eng

35

Symptom

Possible Cause

Resolution

Motor failure

(motor runs at partial

speed)

Electrical

Connections in the top housing

may be loose or damaged.

Contact service center.

Thermal protection

Temperature exceeds

specification. Contact service

center.

Damaged speed

potentiometer

Contact service center.

Propeller is loose,

damaged, or off‑balance

Refer to Removing the
Propeller

.

Motor failure

(motor does not run)

Weak 12 volt trolling

motor battery

Check 12 volt battery charge.

Recharge or replace battery as

required.

Loose or corroded

battery connections

Inspect battery connections for

cleanliness and tightness.

Wiring or electrical

connection faulty

Wire gauge from the battery to

the trolling motor is insufficient.

6 gauge wire is recommended.

Electrical

Check the connector for a loose

or damaged connection.

Contact service center.

Thermal protection

Temperature exceeds

specification. Contact service

center.

Three‑position switch is

damaged

Contact service center.

Fuse on circuit breaker is

open

Replace the fuse or reset the

circuit breaker only after

determining the root cause of

the problem.

Magnets interfering with

armature

Turn off the power and

manually rotate the propeller. If

the propeller does not rotate

freely with a slight magnetic

drag, contact service center.

Boat wiring

Contact service center.