Independent HSM (shared HPU)

Models FlexTest® IIm/GT/SE Controller Hardware

Hydraulic Configurations

247

Independent HSM (shared HPU)

For this multiple controller configuration:

Each controller has an independent hydraulic service manifold (HSM).

An HPU is shared by all connected controllers via Y-cables.

Select HPU/HSM for Power Type on each connected controller.

Path: Config > Edit Hardware > Power Options > Power Type > HPU/
HSM

Shared HSM (with HPU)

FlexTest SE

Emergency Stop

7 8 9

6

5

4

3

2

1

.

0

+/-

enter

cancel

FG

Setup

Status

Scope

Meters

Tuning

Config

Limits

Log

Menu

?

A

B

Recall

Enabled

reset

Rewind

Run

Hold

Stop

Power

Program

Hydraulic

Interlock

Program

Interlock

HPU

HSM

Off

Low

High

Off

Low

High

Navigate

Monitor 1

Monitor 2

FlexTest SE

Emergency Stop

7

8 9

6

5

4

3

2

1

.

0

+/-

enter

cancel

FG

Setup

Status

Scope

Meters

Tuning

Config

Limits

Log

Menu

?

A

B

Recall

Enabled

reset

Rewind

Run

Hold

Stop

Power

Program

Hydraulic

Interlock

Program

Interlock

HPU

HSM

Off

Low

High

Off

Low

High

Navigate

Monitor 1

Monitor 2

Power Type = HPU/HSM

Interlock/Hydraulics

HSM 1

056-126-4xx

J28 HSM

J25 HPU

039-713-8xx

056-316-0xx

Power Type = HPU/HSM

HSM 2

039-713-5xx

HPU

Converter

HPU

039-710-7xx

FlexTest SE

Emergency Stop

7 8 9

6

5

4

3

2

1

.

0

+/-

enter

cancel

FG

Setup

Status

Scope

Meters

Tuning

Config

Limits

Log

Menu

?

A

B

Recall

Enabled

reset

Rewind

Run

Hold

Stop

Power

Program

Hydraulic

Interlock

Program

Interlock

HPU

HSM

Off

Low

High

Off

Low

High

Navigate

Monitor 1

Monitor 2

FlexTest SE

Emergency Stop

7 8 9

6

5

4

3

2

1

.

0

+/-

enter

cancel

FG

Setup

Status

Scope

Meters

Tuning

Config

Limits

Log

Menu

?

A

B

Recall

Enabled

reset

Rewind

Run

Hold

Stop

Power

Program

Hydraulic

Interlock

Program

Interlock

HPU

HSM

Off

Low

High

Off

Low

High

Navigate

Monitor 1

Monitor 2

Power Type = HPU/HSM

Power Type = Slave HSM

Interlock/Hydraulics

HSM

056-126-4xx

J28 HSM

056-316-0xx

HPU

J25 HPU

039-713-7xx

Advertising
This manual is related to the following products: