Bunn Electric Brewing System LCR-2 User Manual

Page 29

Advertising
background image

29

Screen

Displayed

Possible

Cause Troubleshooting

Procedures

Troubleshooting (Continued)

36026 041204

Service Required

Service Required

Service Required

Service Required

Service Required

Service Required

Check water supply shut-off

Service Required

Service Required

Service Required

1. Refill valve stuck open

2. Faulty refill probe

3. Faulty overflow switch

1. Tank Heater failure

2. Triac failure

3. Tank Temp. sensor failure

1. Water shut off to dispenser

2. Inlet Solenoid Valve failure

1. Corresponding Temperature Sensor

Probe wire(s) broken or disconnected

1. Corresponding Temperature Sensor

Probe wire(s) shorted to housing, or to

each other.

OVERFLOW CUP

FULL. EMPTY CUP

HEATING TIME TOO

LONG

CHECK HEATING

CIRCUIT

FILL TIME TOO LONG

CHECK WATER SUPPLY

TANK TEMP SENSOR

OUT OF RANGE

CHECK FOR BAD

CONNECTIONS

TANK TEMP SENSOR

OUT OF RANGE

CHECK WIRE FOR

SHORTS

LEFT BIB EMPTY!

REPLACE PRODUCT

CHECK THRESHOLD

RIGHT BIB EMPTY!

REPLACE PRODUCT

CHECK THRESHOLD

1. Concentrate BIB is Empty.

2. BIB Not properly connected.

3. Tubing kinked or blocked.

4. Empty BIB Warning set too high.

1. Concentrate BIB is Empty.

2. BIB Not properly connected.

3. Tubing kinked or blocked.

4. Empty BIB Warning set too high.

Replace BIB, see loading the

Concentrate

Check BIB Connector Fittings

Check Tubing installation

Check Threshold, see Field Cali-

brating the Empty BIB Warning

Replace BIB, see loading the

Concentrate

Check BIB Connector Fittings

Check Tubing installation

Check Threshold, see Field Cali-

brating the Empty BIB Warning