MTS Landmark Site Prep Guide User Manual
Page 19
Hydraulic Power Unit Specifications
Landmark Test System Site Prep Guide
System Component Specifications
19
Model Specific Specifications
Parameter
505.07 Specification
505.11 Specification
Pump/motor
Maximum Continuous
pressure
Maximum Flow
capacity
Motor rating
Line voltage starter configuration
21 MPa (3000 psi)
22.7 L/m (6 gpm) at 50 Hz
26.5 L/m (7 gpm) at 60 Hz
11.2 Kw (15 hp) at 50/60 Hz
Wye-Delta starter configuration
21 MPa (3000 psi)
41.6 L/m (11 gpm) at 50/60 Hz
18.6 Kw (25 hp) at 50/60 Hz
Water flow rating
(input temperature)
10.0°C (50°F)
15.5°C (60°F)
21.1°C (70°F)
26.7°C (80°F)
32.2°C (90°F)
Heat load (maximum)
3.8 L/m (1.0 gpm)
4.9 L/m (1.3 gpm)
6.1 L/m (1.6 gpm)
8.3 L/m (2.2 gpm)
15.9 L/m (4.2 gpm)
12.3 kW (42,000 Btu/hr)
7.2 L/m (1.9 gpm)
9.1 L/m (2.4 gpm)
12.1 L/m (3.2 gpm)
18.9 L/m (5.0 gpm)
49.2 L/m (13.0 gpm)
20.5 kW (70,000 Btu/hr)
Weight with maximum oil
174 L (46 gal))
450 kg (992 lb)
473 kg (1042 lb)