PAGE 30 —SDW-225SS WELDER/GENERATOR— OPERATION & PARTS MANUAL — REV. # 2 (10/07/05)

SDW-225SS — INSTRUMENTATION

Power Outlets

The generator has the following single-phase 60 Hz, 120/
240 volt receptacles.

z

z

z

z

z

Single Phase

One Duplex NEMA (GFCI) 5-20R (120V, 20 Amp)

One Twist Lock NEMA L14-30R (120/240V, 30 Amp)

One Twist Lock NEMA L5-30R (120V, 30 Amp)

Main Circuit Breaker (2-Pole)

This 2-pole, 25 amp breaker protects the generator from
short circuiting or overloading from the 60 Hz single-phase
load.

GFCI Protection Breaker (Single-Pole)

This single-pole, 20 amp breaker protects the GFCI
receptacle from short circuiting or overloading.

Warning Indicator Lights

The generator has the following warning indicator lights:

Oil Pressure Light

If the oil pressure drops suddenly, the oil pressure light will
go on, and the generator will shut down.

When using a combination of dual receptacles, total load
should not exceed the rated capacity of the generator
set.

Charge Light

The charge light will go on when the battery fails to charge,
and the generator will shut down.

Water Temperature Light

The water temperature light will go on if the temperature
rises to an abnormally high level, and the generator will shut
down.

Idle Control Switch

The generator is provided with an automatic idle control device
for noise suppression and reduced fuel consumption. The
automatic idle control automatically engages under a no-load
condition. With the automatic idle control switched to "ON", the
engine revolutions will automatically drop to about 2600 rpm
(low-speed operation) within 3 seconds after the load stops.
When the operation is resumed, the engine speed is automatically
increased to about 3600 rpm (high speed operation) as soon as
the load is connected.

Fuel Gauge

The fuel gauge is located on top of the generator's enclosure
and allows easy monitoring of the fuel level.

GFCI Receptacle

Before connecting a load to the generator's GFCI receptacle,
push the "Test Button" on the front of receptacle before
connecting the load, to confirm that the receptacle is
functioning correctly.

CAUTI

CAUTI

CAUTI

CAUTI

CAUTION