Mq sp2 slab saw — maintenance – Multiquip SP2S20H20 User Manual

Page 35

Advertising
background image

MQ SP2 SLAB SAW — PARTS & OPERATION MANUAL — REV. #7 (09/08/06) — PAGE 35

Blade Shaft Bearing Replacement

The SP2 slab saw is supported by “tapped base lock collar (w/
set screw)" self-aligning

Blade Shaft Bearings (Figures 51

and 52). These heavy duty bearings support the 1-1/4 blade
shaft, and have grease (zerk) points conveniently located for
service.

Figure 50. Blade Side Bearing (Right Side)

1. It is recommended to replace both left & right bearings at the

same time.

2.

Follow steps 1 thru 4 of Drive V-Belt(s) Replacement &
Tension Adjustments.

3. Remove Drive V-belts.

Figure 51. Pulley Side Bearing (Left Side)

MQ SP2 SLAB SAW — MAINTENANCE

Reference Figure 50 & Figure 51 for steps 4-9

4. Remove

Blade Hex Nuts

(Figures 50 & 51, item 1) and

Outside/Inside Blade Flanges

(Figures 50, item 2 & 3)

5. Loosen

set screws

(Figure 51, item 4) and slide

Pulley

(Figure 51, item 5) off the Blade Shaft. Loosen Bearing set
screw, remove

Bearing Bolt

(Figure 51, item 6) and slide the

Blade Shaft Bearing

(Figure 51, item 8) off the blade shaft.

6. Loosen

set screws

(Figure 50, item 5), remove

Bearing

Bolt

(Figure 50, item 4) and slide the

Blade Shaft Bearing

(Figure 50, item 6) off the blade shaft.

7. Replace

Blade Shaft Bearings

and reassemble the Blade

Shaft Assembly.

8. Re-tension Drive V-belts as shown in the Drive V-Belt(s)

Replacement & Tension Adjustments section.

10. Replace all guards and covers.

Advertising