Maintenance/service – MacDon 5020 Mower Conditioner User Manual

Page 51

Advertising
background image

51

MAINTENANCE/SERVICE



SICKLE AND SICKLE DRIVE (continued)

Wobble Box Maintenance

Mounting Bolts - Check four wobble box
mounting bolts (B) torque after the first 10 hours
operation and every 100 hours thereafter. Torque
should be 200 ft.lbs. (270 N

m). When tightening,

start with the side mounting bolts.

Lubricant - Check wobble box lubricant level
before first operation and every 100 hours
thereafter. To check:

1. Raise header to a point where the wobble box

base is approximately level.

2. Remove breather/dipstick (A). Oil level must

be between end of dipstick and bottom hole (or
groove) in dipstick.

3. Add as required. See "Recommended Lubri-

cants" for specified gear lube and capacity of
box.

4. Replace breather/dipstick.


Change wobble box lubricant after the first 50
hours operation and every 1000 hours (or 3 years)
thereafter.

To drain wobble box, raise header fully and
engage header lift cylinder stops. Remove
breather/dipstick (A) and drain plug (D).



Assembly/Disassembly

If removing wobble box pulley, a 3-jaw puller is
recommended.

When reinstalling drive arm or pulley:

1. Remove any rust or paint from inner spline. For

replacement parts, remove oil/grease with
degreasing agent.


2. Before assembly, apply Loctite® #243 adhesive

(or equivalent) to spline. Apply in two bands (C)
as shown, with one band at end of spline and
one band approximately mid-way.





































USE ADHESIVE FOR ASSEMBLY

WOBBLE BOX MOUNTING BOLTS

& LUBRICANT

B

A

D

Advertising