Instruction

Sheet

www

.prescolite.com

• Prescolite

TollFree

Technical Support

1.888.PRS.4TEC

• Hours: 8am - 5pm ET

101 Corporate Drive • Spartanburg, SC 29303

With representatives offices in principal cities throughout North America.

Copyright 2005, 08/05 revision, All Rights Reserved - Printed in U.S.A.

Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143670100

Instruction

Sheet

INSTALLATION INSTRUCTIONS

RDPSCFT SERIES

DETAIL “A”

1. BEND BRACKETS AS SHOWN IN DETAIL “A”.

INSTALL THE HOUSING FIXTURE IN THE

CEILING USING MOUNTING CHANNEL OR

BAR STOCK (BY OTHERS) PLACED IN THE

ADJUSTABLE MOUNTING BRACKETS.

MOUNT THE HOUSING FIXTURE IN THE

CEILING SO THAT THE WEIGHT OF THE

FIXTURE IS SUPPORTED BY THE MOUNTING

CHANNEL OR BAR AND/OR HANGER WIRES

SECURED TO THE BUILDING STRUCTURE.

2. ADJUST THE HOUSING FIXTURE SO THAT

THE BOTTOM OF THE PLASTER FLANGE IS

FLUSH WITH THE FINISHED CEILING LINE

AND IN ALIGNMENT WITH ADJACENT

FIXTURES. SECURE MOUNTING BRACKETS

BY TIGHTENING WING NUTS ON EITHER

SIDE OF THE FIXTURE.

3. DETERMINE WHICH KNOCKOUT THE

SUPPLY WIRE CONDUIT WILL ENTER THE

BALLAST HOUSING AND CONNECT IT IN

COMPLIANCE WITH THE NATIONAL

ELECTRICAL CODE.

4. LOCATE THE BLACK (LINE), WHITE

(COMMON), & GREEN (GROUND) WIRES OF

THE CONDUIT AND PASS THESE WIRES

THROUGH CENTER HOLE OF PLASTER

FLANGE. LOCATE BLACK (LINE) AND WHITE

(COMMON) WIRES OF THE BALLAST AND

THE FREE GREEN (GROUND) WIRE AND

PASS THESE WIRES THROUGH CENTER

HOLE. LOCATE THE MATE-N-LOCK

CONNECTOR IN THE HOUSING AND PASS IT

THROUGH HOLE.

CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY-INSTALLED WIRING ON THE FIX-

TURE. SAFETY AND PROPER OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY

OF THE WIRING.

(SEE DETAIL “B”

ON NEXT PAGE)

BLACK, WHITE &

GREEN SPLICES

MADE WITH 3

WIRE NUTS

(NOT SUPPLIED)

BALLAST

HOUSING

HOUSING

FIXTURE

MOUNTING

BRACKET

PLASTER

FLANGE

WING

BEND BRACKETS

IN LINE WITH

MARKS

PENDANT

BRACKET

8-32 HEX

SCREWS (2X)

FORSTEP #7

MATE-N-LOCK

CONNECTORS

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information

and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,

and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and

during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by

qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.

Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in

compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by

the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from

product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or

the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.