About the vacuum, Trouble shooting guide, Warning – Pullman Ermator HEPA VAC 1HP 6QT BACPACK (30 ASB) User Manual

Page 2

Advertising
background image

ABOUT THE VACUUM

DISPOSABLE BAG CHANGING:

The recommended bag replacement procedure is as follows:

1. Remove can cap from unit.

2. Tape a 6-mil poly bag over the can cap so that the paper bag is

completely enclosed.

3. Using the poly bag as a glove, disengage the paper bag from the

can cap’s vacuum inlet stem.

4. Seal the poly bag and dispose as prescribed by law.

5. Attach a new paper bag securely to the vacuum inlet and fold the

bottom of the bag lengthwise.

6. Replace the can cap and close the clamps.

7. Thoroughly vacuum the work area to recover any asbestos dust

which may have been dropped.

GASKET REPLACEMENT:

If the air seal gasket is cut or otherwise damaged resulting in an air

leakage, simply remove it from the filter flange and replace it with a
new gasket.

10702 N 46th Street • Tampa, FL 33617

(813)971-2223 • toll free (800) 237-7582

fax (813) 971-6090 • order entry fax (800) 833-8875

www.pullmanholtcorp. com

B700006 1/04

Symptom

Possible Cause(s)

Corrective Action

Loss of Suction

1) Obstruction in hose or wand

1)

Clear hose

2) Clogged air filter assembly

2)

Brush Moleskin filter, replace primary filter

3) Uneven gasket fit

3)

Reposition or replace gasket

4) Dented canister rim

4)

Replace canister

Motor Won’t Run

1) Blown fuse or tripped circuit

1)

Replace fuse or reset circuit

2) Defective cordset

2)

Replace cordset

TROUBLE SHOOTING GUIDE

WARNING

To effectively control asbestos dust emissions from
the vacuum cleaner, All filters must be in place at all
times. If any visible dust emissions are observed in
the vacuum exhaust air stream, stop operations
immediately. If this occurs, the HEPA filter has rup-
tured or must be replaced.

WARNING : Always disconnect power cable from electrical outlet when working on this machine.