3 pin assignment, 4 usb interface, Pin assignment – Robustel M1000 XP User Guide User Manual

Page 15: Usb interface

Advertising
background image

Robustel GoRugged M1000 XP User Guide


RT_UG_M1000 XP_v.1.0.0

19.11.2013

14 / 57

Confidential

Name Color

Status

Function

RSSI

None

Off

Searching for network.

Green

On

Perfect signal quality.

Blinking every 0.5s

Wireless module communication error, no AT command response.

Yellow

On

Average signal (GSM/GPRS/UMTS connections)

Blinking every 1 s

System is configuring via USB, and DB9 serial port is disabled at the same time

Blinking every 0.5 s

Cannot register to network.

RED

On

Exceptional signal (GSM/GPRS/UMTS connections)

Blinking every 0.5s

SIM card detection is fail or PIN error.

2.3 PIN assignment







2.4 USB interface

USB interface can be used for configuration, firmware upgrade and power supply. When USB interface of M1000 XP
is used for configuration as well as power supply, current/voltage output of USB interface which connects to M1000
XP’s USB interface shall at least reach to 1A/5V.
Note: Normally, current/voltage output of laptop’s USB 2.0 interface is only 0.5A/5V. So when you use USB interface
for configuration, you should use power input interface for power supply (please check section 2.9

错误

!

未找到引用

源。

).

DB9 Female Connector

PIN RS232

RS485 (2-wire) Direction

1

Data+ (A)

-

2

RXD

M1000 XP

Device

3

TXD

Device

M1000 XP

4

-

5

GND

-

6

Data- (B)

-

7

RTS

Device

M1000 XP

8

CTS

M1000 XP

Device

9

+5V Output

-