Communicating bath, Using magnetic locks, Cb401b – SDC UR-1 User Manual

Page 6: Cb401a

Advertising
background image

Switch No:

off

off

Position

SW1 SW2

off

SW3

off

SW4

C NO C NO - NO C NC - NO C NC

- +

TRIG A TRIG B

RELAY A

RELAY B

PWR

Communicating Bath

w

D

A

w

D

B

+

-

+

-

DPS

*

DPS

DPS switches should
be in the Closed state
with the doors Closed

*

EMERGENCY

RELEASE

PUSH

TO UNLOCK DOOR

WHT

YEL

ORG

CB401B

RED

RED

LAMP

EMERGENCY

RELEASE

PUSH

TO UNLOCK DOOR

WHT

YEL

ORG

CB401B

RED

RED

LAMP

WHT

YEL

ORG

CB401A

RED

RED

LAMP

Using Magnetic Locks

Door 1

Door 2

Push to

Lock or Unlock

Both Doors

(Inside)

1

2

To

12vdc or 24vdc

Power Supply

+ -

BATHROOM LOCK

BOTH DOORS MUST BE

CLOSED TO LOCK

PUSH TO

LOCK OR UNLOCK

LIGHT ON DOOR LOCKED

Set to “CR Mode”

4 COND

4 COND

4 COND

Magnetic Lock

x

DPS

CB401A

PUSH

BUTTON

(INSIDE)

CB401B

PUSH

BUTTON

4 COND

CB401B

PUSH

BUTTON

4 COND

Magnetic Lock

x

DPS

Method of Operation

Both doors shall be normally unlocked.

System Activation: All doors must be closed to

lock. Pressing the CB401A Push Button will lock
all the doors.

Egress: When the doors are locked, pressing the
CB401A Push Button again unlocks all the doors.

Emergency Release: When the doors are locked,
activating either of the CB401B Emergency Push
Buttons will unlock both doors. Both doors will
unlock automatically via signal from the fire
panel.

When used with an SDC 631RF power supply,
Both doors will unlock automatically via signal
from the fire panel.

TO N/C FIRE ALARM INTERFACE

TO 115 VAC PRIMARY VOLTAGE

2 COND

3 COND

631RF

x

UR1

Power

Supply

MAGNETIC LOCK

MAGNETIC LOCK

P:\INSTALLATION INST\POWER SUPPLY\INST-UR-1.vsd Rev H 04-14 Page 6