Remote system, Installation – Sportsliter Solutions Remote System User Manual

Page 7

Advertising
background image

REMOTE SYSTEM

INSTALLATION

6

TWO ROW CROSSARM ASSY.

(Fig. 8)

(QUANTITY OF FIXTURES SHOWN

IS FOR EXAMPLE ONLY)

T

B

BOTTOM ROW

TOP ROW

ONE ROW CROSSARM ASSY. (Fig. 8)
(QUANTITY OF FIXTURES SHOWN

IS FOR EXAMPLE ONLY)

6 4 2 1 3 5

FIXTURE POSITION NUMBERS

ROW IDENTIFICAITON
T = TOP ROW
M = MIDDLE ROW
B = BOTTOM ROW

T

THREE ROW CROSSARM ASSY (Fig. 8)

REFER TO FIGURE 9 FOR DUAL CIRCUIT LAYOUTS

PLUG WIRING ASSIGNMENTS

ELECTRICAL

PLUG

C = LAMP SOCKET

CENTER CONTACT

S = LAMP SOCKET SHELL
5 = FIXTURE POSITION #

Notes:

• FRONT VIEW OF MALE PLUG SHOWN
• FIXTURE POSITIONS ARE MIRRORED

FOR FEMALE PLUG

NOTE THE “D” SHAPE FOR
PROPER PLUG ORIENTAITON

PLUG WIRING ASSIGNMENTS (Fig. 8)

(QUANTITY OF FIXTURES SHOWN

IS FOR EXAMPLE ONLY)

T

M

B

TOP ROW

BOTTOM ROW

MIDDLE ROW

REMOTE BALLAST BOX

FIXTURE POSITION #’s

3

4

5

6

1

2

BALLAST

REMOTE

BALLAST BOX

Standard Remote Layouts

Front View

DUAL CIRCUIT REMOTE LAYOUTS (FIG. 9)

DUAL CIRCUIT REMOTE

BALLAST BOX

CAT. # REMD-1X00H-X-XX-SH

T

M

B

TOP ROW

BOTTOM ROW

MIDDLE ROW

STANDARD REMOTE LAYOUT FOR 19-30 FIXTURE

(FRONT VIEW)

.

6

4

2

1

3

5

T

M

B

T1

B1

ROW ID

FIXTURE POSITION NO.S

2

ND

TIER

1

ST

TIER

Advertising