SLS0025 SLS Series Instruction-A 1/14

Drawing Number: 268-1117-9801 REV-B

Wiring Instructions: (See Figures 2 & 3)

WARNING!

Units having two or more voltage taps: Remove the wirenut from the desired voltage lead

and connect lead to supply conductor. Replace wirenut on unused voltage lead. Failure to

replace wirenut on unused voltage lead will result in high voltage shock hazard.

NOTE:

All wiring is to be done in the wiring compartment (H) at the rear of the ballast

housing. Use minimum 90 C. SOWA. cord. (14/3 cord is required for fixture using 1500

watt lamps when fixtures are wired for 120V).
1. Loosen (6) cover screws

(I) and set cover aside. Removal of green wire

tether is not recommended.
2. Feed supply cord

(N) into ballast housing through the wireway hole (O)

in the bottom of the wiring compartment (H), through the properly sized
rubber seal

(P) and the center hole in the retaining plate (Q).

3. The end of the cord’s outer jacket should not extend beyond 1” into the
wiring compartment.
4. Tighten the (2) screws

(R) to retain the supply cord.

5. Connect supply power leads to ballast primary leads in accordance with
local and NEC Codes.
6. Attach ground lead to green ground screw inside wiring compartment
and replace cover

(J), ensuring that no wires are pinched inside housing.

Target Aiming Instructions: (See Figures 2, 4A, 4B, 4C)
(Aiming Sight “SLSAIMINGSIGHTAXL” to be ordered separately)
1. Install aiming sight bracket

(S) in the socket housing (C) as shown in

Figure 4a. Ensure alignment to boss

(T).

2. Loosen main fixture mounting bolt

(M) add socket housing

retaining bolt

(U).

3. Look through the hole at the outermost end of the aiming sight bracket.
4. Align center of hole with the top left edge of lens door retaining latch

(V)

as shown in Figure 4b.
5. Aim the fixture by aligning the hole and the left edge of the latch with
the desired aiming location. See Figure 4c.
6. Tighten the main mounting bolt

(M) to 150 ft. lbs. and the socket

housing retaining bolt

(U) to 35-40 ft. lbs.

7. Rotate the aiming/repositioning stop bracket

(X) BACKWARDS until

the stop rest firmly against the tab on the socket housing and tighten the
retaining screw

(W). (See Figure 1c).

Fast Aim Aiming Instructions:
NOTE: Target aiming is the IES preferred aiming method. Some minor

adjustments may be required as with any preset aiming system.

To position the fixture horizontally: (See Figure 2)
1. Loosen main fixture mounting bolt

(M).

2. Rotate the fixture to desired position using the horizontal aiming indicator

(Y) and the degree markings on the horizontal aiming plate (K).

3. Tighten the main mounting bolt

(M) to 150 ft. lbs.

To position the fixture vertically: (See Figure 1c)
4. Loosen the screw (W) holding the vertical aiming/repositioning
stop bracket

(X).

5. Rotate the bracket to the desired position using arrow indicator

(Z) on

the ballast housing and degree markings on the bracket.
6. Tighten the bracket retaining screw

(W).

7. Loosen the socket housing retaining bolt

(U) and rotate the socket/

reflector assembly forward until it rests against the aiming
stop bracket

(X).

8. Tighten the socket housing retaining bolt

(U) to 35-40 ft. lbs.

Figure 4a

U

T

C

AA

S

H

K

AF

M

AB

AC

Y

Figure 2

J

Figure 3

R
Q

P

N

O

Figure 4b

S

E

V

LINE OF

SIGHT

Figure 4c

S

U

Up-Aiming Instructions: (See Figure 4A)
For aiming above horizontal, a drain hole knockout is provided on the

back of the socket housing. The use of safety glasses is recommended. To

open the drain hole, place a flat blade screwdriver directly between the

two indicator marks

(AA) on the back of the socket housing and strike the

handle of the screwdriver sharply with a hammer. Remove any debris from

the socket housing

(C).


Relamping Instructions:
1. Ensure repositioning stop

(X) is set and loosen the socket housing

retaining bolt

(U).

2. Rotate socket/reflector assembly back to gain access to
lamp compartment.
3. Release latches and swing lens door assembly open.
4. After relamping, reverse steps 2 & 3. Ensure proper seal of lens
door gasket.
5. Tighten the socket housing bolt

(U) to 35-40 ft. lbs.

SLS SERIES FLOODLIGHT

INSTALLATION AND SERVICING INSTRUCTIONS

Advertising