Service menu content – Summit WMC64P Service Manual User Manual

Page 10

Advertising
background image

Service manual WM70.C

10

1 Service

11 Info

SP: XXXX

Date the software was programmed (Year_Week)

CM: XXXX

Date of manufacture of the control unit (Year_Week)

SW:

Software version

SW:

Software version

NC:

Number of cycles/programmes run

NC 1:

Number of cycles for Programme 1

NC 2:

Number of cycles for Programme 2

NC 28:

Number of cycles for Programme 28

12 Fault
scenarios

Fault 1

Shows current fault. The display shows Fault name_Programme
number_Number of cycles_ Index number.
Example: Thermistor fault_Pr5_9_(1)

Fault 2
Fault 3

13
Diagnostics

Test
Test valve 1

Inlet valve 1 is open.

Test valve 2

Inlet valve 2 is open.

Test valve SM Inlet valve 1 and 2 are open.
Test valve 3

Inlet valve 3 is open.

Test heater

Heater on up to max. 60°C.

Test motor

The motor normally runs at 49 rpm.

Test drain

The drainage pump runs.

Test spin

The machine runs a spin sequence, the drainage pump runs.

Test door

The door lock is activated and the door opens. Returns to the
programme menu.

14 Total
reset

The machine is restored to its factory settings. Returns to the
programme menu after Total reset.

15 ABC
reset

The custom programmes (Pr20-Pr22) are reset. Returns to the
programme menu after ABC reset.

Return

Press the Key button (S5) to return to 1 Service.

Service menu content