Troubleshooting, Fault indicators cont – Summit TDC111V Service Manual User Manual

Page 27

Advertising
background image

Display

Cause

Action

Thermistor fault,

Thermistor Fault,

Thermistor fault,

Termistorfel, Termostat

fejl, Termistor,

Termistorivika, Défaut

, Termistorfehler,

Termistore , Fallo ,

Teрмистoр, Temp. sensor

fout

1. Thermistor circuit open
2. Thermistor malfunction

Service action:
Check the thermistor. Replace if
necessary.

Clean condenser, Rengör

kondensor, Rens kon.

sator, Rens kon.sator,

Puhdista lauhdutin,

Nettoyage condenseur,

Reinigen kondensor, Pulizia

condensatore, Limpiar

condensador, Oчистить

кoндeнсaтoр, Kondenser

reinigen

1. Displayed according to the interval set
in the service menu.

Check whether the customer has:
• Cleaned the condenser/evaporator
and filter.
• Cleaned the other air passages.

Clean Lint Filter, Clean

Lint Filter, Rengör filtret,

Rengør fnugfilter, Rens

filter, Puhdista sihti,

Nettoyage filtre, Reinig

filter, Pulizia filtro, Limpie

el filtro, Oчистить фильтp,

Sieb reinigen

1. Displayed according to the interval set
in the service menu.

Check whether the customer has:
• Cleaned the lint filter.

Clean auto filter, Rengör

autofilter, Rens aut. filter,

Rengjøring autofilter, Puhd.

autom. suodatin, Nett. filtre

auto, Auto. filter reinigen,

Pulizia filtro auto, Limpiar

el autofiltro, Очистите

автофильтр, Autofilter

reinigen

1. Displayed according to the interval set
in the service menu.

Check whether the customer has:
• Cleaned the water filter.

H

P

(h

ea

t p

um

p)

Clean filter, Rengör filter,

Rens filter, Rengjøring

filter, Puhd. suodatin,

Nett. Filtre, Filter reinigen,

Pulizia filtro, Limpiar el

filtro, Очистите фильтр,

Filter reinigen

1. Displayed according to the interval set
in the service menu.

Check whether the customer has:
• Cleaned the evaporator filter (net filter
+ foam filter) and the evaporator.

H

P

(h

ea

t p

um

p)

After carrying out corrective actions as above, reset the fault indication on the display by switching off the machine at
the main power switch.

Fault indicators cont.

Troubleshooting

Service Manual TD70.C

27