Component description – Summit TDC111V Service Manual User Manual

Page 9

Advertising
background image

Component description

Components and measurement values
The specified resistance values apply at room temperature (about 20°C/68°F). Values within
±10% are considered normal.

Article no.

Component

Measurement value

Comment

80 839 15

Motor 50 Hz,

220/240 V

Winding resistance:

cable colour red-white 26.5

cable colour red-blue 53.5

cable colour white-blue

27.0 Ω

Current: 0.7 A; 140 W;

2850 rpm

80 839 16

Motor 60 Hz,

220/240 V

Winding resistance:

cable colour red-white 26.5

cable colour red-blue 53.5

cable colour white-blue

27.0 Ω

Current: 0.7 A; 140 W;

3300 rpm

The motor is a 2-pin motor and is

directly connected to the fan for

internal air and the gearing for driving

the cylinder. On condenser dryers, the

motor also drives the fan for external air.

80 903 13

Capacitor

8 μF

50 Hz

80 903 14

Capacitor

6 μF

60 Hz

80 902 70

Capacitor heat pump

17 μF

50 Hz

80 902 71

Capacitor heat pump

60 Hz

80 821 28

Condensate pump

50 Hz

80 846 48

Condensate pump

60 Hz

80 762 02

EMC-filter with inductor

The filter eliminates interference to and

from the machine.

80 833 44

Thermistor

4.8 kΩ (at 25°C)

The thermistor controls temperature

regulation. If the thermistor is short-

circuited or detaches from the control

unit, the programme is stopped.

80 773 85

Thermostat 150

150°C automatic

The thermostat/overheating cut-out

stops the programme if the temperature

becomes too high.

80 792 00

Thermostat 135

135°C automatic

80 902 24

Thermostat 110

110°C automatic

80 761 04

Door switch

The front door triggers a door switch

which stops the programme when the

door is open. If the door has been opened

and closed during the programme the

machine must be restarted using the

Start/Stop button.

80 761 03

Microswitch float

Overflow guard

If both containers in the tumble dryer

are full the programme is stopped by

a float switch installed in the lower

container. “Over flow” is indicated on

the display.

Electrical connection

Condenser 1950W/10A-

2500W/16A

Vented 1950W/10A-

3000W/16A

Heat pump 1300W/10A

Heating Water Circuit

1950W/10A

The machine is delivered as single phase

and can be switched between 10 A and 16

A. The control buttons are used to make

the switch via the software. Does not apply

to Heat Pump or Heating Water Circuit.

Service Manual TD70.C

9