Conversions – Summit GC424BGL User Manual

Page 10

Advertising
background image

9

CONVERSIONS

Replacing Nozzles

The burners can be adapted to suit different
types of gas by fitting the nozzles that corres-
pond to the gas used. To do this, it is
necessary to remove the burner heads and
use a straight key "B", to unscrew the nozzle
"A" (see Fig. 7) and replace it with a nozzle
corresponding to the gas used.

Be sure the nozzle is seated tightly.

After making these replacements, the technician must regulate the burners
as described in Adjustments
on the previous page and apply the label
corresponding to the new gas type in place of that previously applied. This
label is contained in the spare nozzle bag.

For ease of the fitter, we have prepared a table indicating the flow capacities, the
heat capacities of the burners, the diameter of the nozzles and the working
pressure for the various types of gas.

Burners

Gas

Normal

Pressure,

inches water

column

Injector

Diameter,
1/100 mm

Nominal Heat

Input (Btu/h)

No.

Description

Min.

Max.

2

Rapid

Propane HD-5
Natural Gas

11

7

83

145

2400
2400

8350
8350

3

Semirapid

Propane HD-5
Natural Gas

11

7

58

100

2050
1700

4350
4350

4

Semirapid

Propane HD-5
Natural Gas

11

7

58

100

2050
1700

4350
4350

5

Auxiliary

Propane HD-5
Natural Gas

11

7

50
90

1200
1400

3400
3400

2

5

2

5

4

3

Arrangement
of Burners

Fig. 7

Advertising