When the appliance is connected to electrical power by a socket:

Fit a standard plug suited to the load indicated on the data label to the cable.

Fit the wires following Fig. 5, noting the following correspondences:
Letter L (live) = wire
Letter N (neutral) = wire

Ground symbol = green or yellow-green wire

Never use adapters or shunts for connection since these could create false
contacts and lead to dangerous overheating.

The outlet must be accessible after the cooktop is built in.

When the appliance is connected directly to the electrical main:

Install an omnipolar circuit-breaker between the appliance and the electrical
main. This circuit-breaker should be sized in compliance with local installation
regulations.

Remember that the ground wire must not be interrupted by the circuit-breaker.

For optimum safety, the electrical connection may also be protected by a high-
sensitivity differential circuit-breaker.

You are strongly advised to fix the yellow-green ground wire to an efficient
grounding system